Tell you how to configure the switch in the home distribution box?
When we renovate our home with hydropower, most families will reconfigure the distribution box in our home. This is because the switch in the distribution box that the developer has configured is configured according to the basic use requirements, and it can not meet the use of each family. So at this time, we should configure the switch according to the actual power consumption in our home.
The distribution box switches in the home are configured according to our electricity consumption. The specific process is as follows: first, according to the power consumption in our room, a calculated current is calculated when the electrical appliances are used in this room; Then, the wires can be selected according to the current in the room; According to the current carrying capacity of the conductor, we can choose the switch that matches it.
The specific steps of switch configuration in the home distribution box are as follows:
One step is to divide the power consumption in our home into circuits. The common way to divide the electricity back is as follows: one circuit for common socket, one circuit for wall mounted air conditioner, one circuit for cabinet air conditioner, one circuit for ordinary lighting, one circuit for kitchen and one circuit for bathroom.
The second step is to calculate the power consumption in each circuit, and then calculate the calculated current of the circuit according to our electricity consumption. The third step can select the corresponding wire according to the calculated current. After selecting the conductor, the switch matching with the conductor can be selected according to the safe load flow of the conductor. The configuration of the switch commonly used in the home distribution box may be said to everyone above. Some friends still don't know what to do. Let's share some of the current more common, home switch configuration. The distribution box and main switch in the home are all 2p air switches, the specific models are c40a, c50a, or C63A. Generally, the switch of lighting circuit is 2p or 1p + n air switch. Basically, C16 A is used. For the switches of common socket circuit and wall mounted air conditioning socket circuit, it is recommended that you choose 2p leakage protection switch or 1p + n leakage protection switch. The size selection says that C16 A is basically OK.
It is the switch of kitchen circuit socket and toilet circuit, and the switch of cabinet air conditioning circuit. These loop switches are also recommended to select 2p leakage protection switch or 1p + n leakage protection switch. The size of the switch is that you choose c20a or c25a.
If we still don't have the switch in the distribution box, we can sell the switch directly, and tell him the size of our house and what kind of household appliances we have in the house. They will configure you based on these data, generally speaking, there is no problem. So if we really can't match it by ourselves, we will sell the switch directly, so that they can match it. It is simple and convenient.